Summary
Air source heat pumps (ASHPs) have been widely used for space cooling in recent years. When a space cooling ASHP unit is operated in an ambience with poor air quality, fouling of its outdoor coil can be easily built up, leading to a significant drop in the operating efficiency and output cooling capacity of the ASHP unit. Therefore, as a follow-up to a previous related study, a study to develop a novel defouling initiation method for the fouled outdoor coil in a space cooling ASHP unit based on its measurable char- acteristic ambient and operating temperatures has been carried out and the study results are reported in this paper. Firstly, a characteristic parameter of TTT, which can be evaluated based on ambient air Temperature, outdoor coil metal surface Temperature and outdoor coil outlet air Temperature, is defined. Secondly, the development of the novel defouling initiation method is detailed. Finally, further field comative studies using the developed novel defouling initiation method have been carried out, and the study results demonstrated that the novel defouling initiation method can provide an accurate and convenient way to initiate defouling of the fouled outdoor coil in an ASHP unit at a reasonable defouling frequency to ensure its best possible operating performances.
Available documents
Format PDF
Pages: 171–179
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: A novel defouling initiation method for a space cooling ASHP unit based on its measurable characteristic ambient and operating temperatures.
- Record ID : 30026577
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Publication date: 2019/08
- DOI: http://dx.doi.org/doi.org/10.1016/j.ijrefrig.2019.03.039
Links
See other articles in this issue (50)
See the source
Indexing
- Themes: Heat pumps techniques
- Keywords: Fan-coil unit; Correlation; Temperature; Air-source system; Coil; Heat pump; Testing; Fouling; Air conditioning
-
Operating performances of a space heating ASHP ...
- Author(s) : LIU J., WEI W., SUN Y., et al.
- Date : 2018/04
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 88
- Formats : PDF
View record
-
MEASUREMENT OF THE HEAT CAPACITY OF FAN-COIL UN...
- Author(s) : CAON S.
- Date : 1984/09
- Languages : Italian
- Source: Cond. Aria - vol. 28 - n. 9
View record
-
Initial test campaign of an innovative dual sou...
- Author(s) : MARCHANTE-AVELLANEDA J., CORBERÁN J. M., CAZORLA-MARÍN A., et al.
- Date : 2018/06/19
- Languages : English
- Source: CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
View record
-
Analysis of the refrigerant‐side temperature pr...
- Author(s) : SIERES J., ORTEGA I., CERDEIRA F., SANTOS J. M., ALVAREZ E.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Les ventilo-convecteurs : une solution efficace...
- Author(s) : ROUSSET J. L.
- Date : 2001
- Languages : French
- Source: Qualita - n. 64
View record