AN EXPERIMENTAL STUDY ON THE DYNAMIC BEHAVIOUR OF MICROMETER-SIZE GAP BY CYLINDER PRESSURE AND TEMPERATURE UNDER THE ROTARY COMPRESSOR OPERATION.

Summary

THE GAP SENSOR WHICH IS COMPACT, HEAT PROOF AND LOWER TEMPERATURE DRIFT HAS BEEN DEVELOPED TO UNDERSTAND SEVERAL GAPS IN THE ORDER OF SOME MICROMETERS UNDER THE COMPRESSOR OPERATION. THE GAPS BETWEEN THE BLADE AND THE BLADE GUIDE GROOVE AS WELL AS THAT BETWEEN THE ROTOR AND THE CYLINDER WERE MEASURED WITH THE GAP SENSOR DEVELOPED. RESPECTIVE GAPS WERE FOUND TO BE SMALLER THAN THOSE PRE-ESTIMATED, AND IT WAS UNDERSTOOD THAT ONE OF FACTORS WAS DEFORMATION BY THE CYLINDER PRESSURE.

Details

  • Original title: AN EXPERIMENTAL STUDY ON THE DYNAMIC BEHAVIOUR OF MICROMETER-SIZE GAP BY CYLINDER PRESSURE AND TEMPERATURE UNDER THE ROTARY COMPRESSOR OPERATION.
  • Record ID : 1991-2548
  • Languages: English
  • Publication date: 1990/07/17
  • Source: Source: Proc. 1990 int. Compress. Eng. Conf., Purdue Univ.
    vol. 2; 845-852; 10 fig.; 1 tabl.; 2 ref.
  • Document available for consultation in the library of the IIR headquarters only.