Analogue adaptive vibration cancellation system for Stirling cryocoolers.
Author(s) : COLLINS S. A., FLOTOW A. H. von, PADUANO J. D.
Type of article: Article
Summary
The system uses a custom-designed multi-axis counterbalance and an analogue implementation of an adaptive feedforward compensator. A non-linearity associated with the counterbalance is modelled, and its effect on the closed-loop system is assessed. In an initial test, the third harmonic of the expander's axial force was cancelled by 22-38 decibels over a wide range of drive frequencies, with little effect on the other harmonics or the lateral vibrations.
Details
- Original title: Analogue adaptive vibration cancellation system for Stirling cryocoolers.
- Record ID : 1995-1349
- Languages: English
- Source: Cryogenics - vol. 34 - n. 5
- Publication date: 1994/05
Links
See other articles in this issue (17)
See the source
Indexing
-
Cryocooler resonance characterization.
- Author(s) : ROSS R. G. Jr, JOHNSON D. L., MON G. R., SMEDLEY G.
- Date : 1994/05
- Languages : English
- Source: Cryogenics - vol. 34 - n. 5
View record
-
Diaphragm Stirling cryocooler developments.
- Author(s) : STACY W. D.
- Date : 1992
- Languages : English
- Source: Cryogenics - vol. 32 - n. 2
View record
-
Performance evaluation of spaceborne cryocooler...
- Author(s) : KWON S. C., JEON S. H., OH H. U.
- Date : 2015/04
- Languages : English
- Source: Cryogenics - vol. 67
View record
-
Development of Stirling Cryocooler in space.
- Author(s) : FUKUDA T., TAKAGI M., TAKAKUSAGI T., FURUKAWA M., ISHII Y.
- Date : 1992
- Languages : Japanese
- Source: Cryogenics/ Cryog. Eng. - vol. 27 - n. 3
View record
-
Development and preflight qualification testing...
- Author(s) : JONES B. G., SCULL S. R.
- Date : 1992
- Languages : English
- Source: Cryogenics - vol. 32 - n. 10
View record