CAPACITY CONTROL OF ROTARY COMPRESSORS BY CYLINDER BY-PASS.

Author(s) : HORI M.

Summary

ROTARY COMPRESSORS ARE EQUIPPED WITH A BY-PASS PORT FOR VARYING THE COMPRESSOR VOLUME. THE AUTHORS SIMULATED THE GENERAL CHARACTERISTICS BY COMPUTER AND, IN THE SAME TIME, THEY TESTED THE SUITABILITY OF THIS SIMULATION. THEY ANALYSED CAPACITY AND OBSERVED THE LOSS OF THE BY-PASS SYSTEM ON A CYLINDER ; IT APPEARED THAT BY-PASS LOSS IS, FOR A CAPACITY CONTROL RANGING BETWEEN 100 AND 50%, LOWER THAN 5% COMPARED TO MOTOR CAPACITY. ITS APPLICATION TO AIR CONDITIONING BY A HEAT PUMP INCREASED HEATING CAPACITY BY 18%.

Available documents

Format PDF

Pages: 1037-1043

This document is to be digitised and will be available within 10 working days

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: CAPACITY CONTROL OF ROTARY COMPRESSORS BY CYLINDER BY-PASS.
  • Record ID : 1986-0549
  • Languages: English
  • Source: [Refrigeration serving humanity]. Proceedings of the XVIth international Congress of Refrigeration.
  • Publication date: 1983/08/07
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (541)
See the conference proceedings