Summary
From the analysis on energy consumption, a reclaimed water source heat pump based combined heating and cooling system was proposed to use the energy in available resources from waste-water treatment plants. In the present system, a reclaimed water source heat pump is used to absorb the heat of waste water from the plant to meet the heating need in the thermophilic anaerobic digestion process. Then the waste water with lower temperature is applied to cool the plant buildings in summer. The effect of the evaporating temperature on the system efficiency was analyzed on the basis of the energy efficiency index. The calculation results indicate that the combined heating and cooling system proposed can reduce the energy consumption for the thermophilic anaerobic digestion process and the building cooling in municipal waste-water treatment plants by 30% in summer and 40% in winter.
Available documents
Format PDF
Pages: pp. 1-5
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 2010-2039
- Languages: Chinese
- Source: Journal of Refrigeration - vol. 31 - n. 6
- Publication date: 2010/12
- DOI: http://dx.doi.org/10.3969/j.issn.0253-4339.2010.06.001
Links
See other articles in this issue (10)
See the source
-
Heat pumps and buildings energy efficient heati...
- Author(s) : HALOZAN H.
- Date : 2013/09/02
- Languages : English
- Source: Compressors 2013: 8th International Conference on Compressors and Coolants.
- Formats : PDF
View record
-
Actual effectiveness of heat pump systems for e...
- Author(s) : SAWACHI T., MIURA H., HOSOI A., et al.
- Date : 2010/02/17
- Languages : English
- Source: Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
View record
-
Year-round provision of dwelling and public bui...
- Author(s) : KOKORIN O. Â., TOVARAS N. V., SHULGIN Yu. V., et al.
- Date : 2010
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 7
View record
-
Operating cost assessment of space conditioning...
- Author(s) : LU Z., BRAUN J. E., ZIVIANI D.
- Date : 2022
- Languages : English
- Source: 2022 Purdue Conferences. 7th International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record
-
Application of groundwater-source water-loop he...
- Author(s) : LIU J., WEI Z., ZHANG M.
- Date : 2012/09
- Languages : Chinese
- Source: HV & AC - vol. 42 - n. 268
- Formats : PDF