Energy optimization of a ground source heat pump system for heating and cooling in an office building.

Optimización energética de un sistema de calefacción y refrigeración con bomba de calor geotérmica en un edificio de oficinas.

Author(s) : CORBERÁN J. M., MONTAGUD C., HESELHAUS F.

Type of article: Article

Summary

The aim of the paper is to examine the influence of the frequency of the water circulation pumps of the indoor (water distribution system) and outdoor (ground source) loops in the overall system performance in order to make an energy optimization. The paper first presents an analysis of the problem and the reasons for the existence of an optimum. Second, it presents the layout of the system, and describes the instrumentation employed. The cold (summer)/hot (winter) water is supplied to a series of fancoil units conveniently distributed in the conditioned area of the building. The ground heat exchanger is composed of 6 boreholes, 50 m deep each. After presenting the system, a sample of the performance of the system along one day is presented and discussed. Previous experimental campaigns consisting of fixing a constant frequency for each circulation pump along a whole day indicated a high potential for energy savings. However, intrinsical variation of the ambient conditions and of the conditions of usage induced variations in the performance which do not allow an accurate estimation of the energy savings due to the pump speed optimization. The experimental optimization studies presented in the paper consisted of several tests of pseudo-random sequence of frequency steps for both internal and external circulation pumps carried out during a single day. For this purpose, two frequency inverters were installed. This method allowed finding an optimal operating frequency for the circulation pumps, which improves the system performance and provides energy savings. Results clearly indicate a large energy savings potential for this installation type if frequency inverters are used to vary the speed of the circulation pumps and an integrated intelligent control is applied.

Available documents

Format PDF

Pages: 36-43 (7 p.)

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Optimización energética de un sistema de calefacción y refrigeración con bomba de calor geotérmica en un edificio de oficinas.
  • Record ID : 30007562
  • Languages: Spanish
  • Source: Frío Calor Aire acondicionado - vol. 41 - n. 454
  • Publication date: 2013/01

Links


See other articles in this issue (4)
See the source