Condensation heat transfer coefficient measurements and flow pattern visualizations of R515B and R450A inside a 3.4 mm diameter channel.
Number: 2408
Author(s) : AZZOLIN M., BERTO A., BORTOLIN S., MATTIUZZO N., DEL COL D.
Summary
An alternative low Global Warming Potential (GWP) refrigerant that could be used to replace R134a in heat pumps, refrigeration and air-conditioning systems is the hydrofluoroolefin R1234ze(E). As a drawback, R1234ze(E) is classified as a mildly flammable fluid (A2L ANSI/ASHRAE classification) and it presents a lower volumetric cooling capacity compared to R134a. In the search for non-flammable R134a substitutes, hydrofluorocarbon/hydrofluoroolefin binary mixtures can be considered. R515B (R1234ze(E)/R227ea at 91.1/8.9% by mass) and R450A (R1234ze(E)/R134a at 58.0/42.0% by mass) are two alternatives classified as A1 (not flammable). R515B is an azeotropic mixture with GWP100-years = 299, whereas R450A is a near-azeotropic blend (temperature glide 0.6 K at 40 °C) with GWP100-years = 547.
In this work, condensation tests are performed with R515B and R450A inside a circular cross-section channel with an inner diameter equal to 3.4 mm. The test section is composed of two copper heat exchangers designed for the measurement of the quasi-local heat transfer coefficient. A glass tube, located between the two diabatic parts of the test section allows the visualization of the two-phase flow patterns by a high-speed camera. Heat transfer coefficients are measured at 40 °C mean saturation temperature and mass flux between 50 and 300 kg m-2 s-1. The prediction accuracy of condensation heat transfer models is then assessed against the experimental results. Measured heat transfer coefficients are also compared with those of R1234ze(E) at the same operative conditions.
Regarding the diameter of the present test tube, it is worthy to point out that small diameter tubes are often employed in finned coil heat exchangers and minichannel heat exchangers are a common solution for air-cooled condensers.
Available documents
Format PDF
Pages: 9 p.
Available
Free
Details
- Original title: Condensation heat transfer coefficient measurements and flow pattern visualizations of R515B and R450A inside a 3.4 mm diameter channel.
- Record ID : 30030715
- Languages: English
- Subject: Technology
- Source: 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2022
Links
See other articles from the proceedings (224)
See the conference proceedings
-
Condensation heat transfer of R1234ze(E) and R1...
- Author(s) : CATTELAN G., DIANI A., AZZOLIN M.
- Date : 2022/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 143
- Formats : PDF
View record
-
Condensation of refrigerant R450A inside a mini...
- Author(s) : AL-BADRI A. R.
- Date : 2024/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 159
- Formats : PDF
View record
-
Study on the vapor-liquid equilibrium of new HF...
- Author(s) : YANG W., HE G., WANG Z., LI X., ZHANG Z.
- Date : 2023/04/05
- Languages : English
- Source: 3rd IIR conference on HFO Refrigerants and low GWP Blends. Shanghai, China.
- Formats : PDF
View record
-
Boiling enhancement of R1234ze(E) on microstruc...
- Author(s) : HIRAHARA M., HAMASAKI S., SUZUKI D., LIU Y., KONDOU C.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Boiling of the new low-GWP refrigerants R1234ze...
- Author(s) : LONGO G. A., MANCIN S., RIGHETTI G., et al.
- Date : 2019/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
View record