IIR document

Cooling in Mediterranean hotels during summertime experience from the NEZEH (Nearly Zero Energy Hotels) project.

Author(s) : TSOUTSOS T., TOURNAKI S., FRANGOU M., et al.

Summary

In Mediterranean areas, during summertime, the demand for electricity greatly increases due to the extensive use of heating, ventilation, and air conditioning (HVAC) systems, increasing the peak electric load, causing major problems in the electric supply. The seasonal temperatures have a direct impact on the pattern of the power demand in the area, so most buildings are cooled by electrically powered, conventional, vapour compression systems.
The European Policy (EPBD recast, Energy Efficiency Directive) motivates the Member States to establish a long-term strategy for mobilizing investment in the renovation of the national stock of residential and commercial buildings, both public and private.
This paper presents the first results of the actual performance of Mediterranean hotels in Greece, Croatia, Italy and Spain analyzed in the framework of the nearly Zero Energy Hotels (neZEH) project putting emphasis on the cooling demand due to their seasonal summertime operation.
The applied methodology consists of providing technical advice, demonstrating the feasibility and sustainability of investments towards zero energy, undertaking training and capacity building activities, as well as promoting front runners at national, regional and EU level.
Amongst the measures which will improve the HVAC consumption, simple interventions are also included offering the most attractive payback (i.e installation of thermostatic valves or stop leaks improvements). The most common economically appealing are Building Energy Management System (BEMS), the replacement of current heat pumps by more efficient ones, but also the outdoor redesign for improved microclimate.

Available documents

Format PDF

Pages: 8

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Cooling in Mediterranean hotels during summertime experience from the NEZEH (Nearly Zero Energy Hotels) project.
  • Record ID : 30017524
  • Languages: English
  • Subject: Environment
  • Source: 4th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Auckland, New Zealand, April 7-9, 2016.
  • Publication date: 2016/04/07
  • DOI: http://dx.doi.org/10.18462/iir.iccc.2016.0030

Links


See other articles from the proceedings (63)
See the conference proceedings