Cooling power of the dilution refrigerator with a perfect continuous counterflow heat exchanger.

Author(s) : TAKANO Y.

Type of article: Article

Summary

Unlike the original solution by Frossati et al, the present solution gives the refrigerator cooling power which is in good agreement with experimental data over the entire temperature range. An approximate expression for the cooling power is discussed which simplifies the prediction of the cooling rate of a large thermal load such as a copper nuclear-demagnetization stage.

Details

  • Original title: Cooling power of the dilution refrigerator with a perfect continuous counterflow heat exchanger.
  • Record ID : 1995-1344
  • Languages: English
  • Source: Rev. sci. Instrum. - vol. 65 - n. 5
  • Publication date: 1994/05