LOW TEMPERATURE HEAT EXCHANGER FOR AN HE3-HE4 DILUTION REFRIGERATOR.
Author(s) : PAVLOV V. N.
Type of article: Article
Summary
THE DESIGN AND TECHNIQUES FOR CONSTRUCTING A STEP-HEAT EXCHANGER USING SINTERED COPPER POWDER ARE REPORTED. THE RESULTS OF APPLYING IT TO A HE3-HE4 COMBINED DILUTION REFRIGERATOR ARE PRESENTED. THE PERFORMANCE OF THE MIXING CHAMBER IN A SINGLE-CYCLE MODE IS CONSIDERED.
Details
- Original title: LOW TEMPERATURE HEAT EXCHANGER FOR AN HE3-HE4 DILUTION REFRIGERATOR.
- Record ID : 1983-0366
- Languages: English
- Source: Cryogenics - vol. 22 - n. 6
- Publication date: 1982
Links
See other articles in this issue (7)
See the source
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Dilution; Cryocooler; Cryogenics; Heat exchanger
-