Cryocooler directly cooled 6 T niobium-titanium superconducting magnet system with 180 mm room temperature bore.

Summary

The technical features of this magnet system are a 4 K Gifford-McMahon refrigerator using magnetic regenerator material and a high-critical temperature BSCCO superconducting current lead. The niobium-titanium coil was directly cooled by the refrigerator without liquid helium and it took about 21 hours for the niobium-titanium coil to be cooled from room temperature to below 4 K.

Details

  • Original title: Cryocooler directly cooled 6 T niobium-titanium superconducting magnet system with 180 mm room temperature bore.
  • Record ID : 1995-2766
  • Languages: English
  • Source: Proceedings of the 15th international cryogenic engineering conference. ICEC 15.
  • Publication date: 1994/06/07