Summary
The cycle performance of the novel 5 mm outer diameter (OD) finned tube heat exchangers (FTHX) with different helix angles (1°, 6°) were investigated as indoor unit in split air conditioning systems to be compared with those of the conventional indoor ones (5 mm and 7 mm FTHX with helix angle of 18°). Conventional T-splitter of the outdoor heat exchanger (HX) was afterward replaced by a Y-splitter and numbers of U-tubes in the two bypasses were adjusted to balance the heat exchange amount of two different bypasses. At first, experimental results showed that the 5 mm system with helix angle of 6° was superior to those 5 mm systems with helix angles of 1° and 18° but still inferior to the conventional 7 mm system, in aspects of capacity and coefficient of performance (COP) both in cooling and heating mode. But after the adjustments, performance of the 5 mm system with helix angle of 6° experienced a 1.5% and 0.7% higher capacity both in cooling and heating mode, respectively, and a 1.7% higher heating COP in spite of a 0.7% lower cooling COP. The system adopting the 5 mm tubes with the helix angle of 6° after adjustments is demonstrated that it can commendably ease material pressure and meanwhile promote the cycle performance.
Details
- Original title: Cycle performance of air conditioning system based on finned tube heat exchangers with different helix angles.
- Record ID : 30014870
- Languages: English
- Source: Applied Thermal Engineering - vol. 78
- Publication date: 2015/03
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2014.12.010
Links
See other articles in this issue (19)
See the source
Indexing
-
Applicable studies of parallel flow heat exchan...
- Author(s) : LIN C.
- Date : 2011/12
- Languages : Chinese
- Source: Refrigeration - vol. 30 - n. 4
View record
-
Numerical model of dusty-water bridge forming b...
- Author(s) : YANG Y., ZHUANG D., DING G., ZHAN F.
- Date : 2020/09
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 117
- Formats : PDF
View record
-
Stosowanie rur gestozebrowanych w poziomych skr...
- Author(s) : BONCA Z.
- Date : 2005/05
- Languages : Polish
- Source: Technika Chlodnicza i Klimatyzacyjna - vol. 12 - n. 5
- Formats : PDF
View record
-
Optimal configuration of cross flow plate finne...
- Author(s) : SAECHAN P., WONGWISES S.
- Date : 2008/11
- Languages : English
- Source: International Journal of thermal Sciences - vol. 47 - n. 11
View record
-
An experimental and computational study of appr...
- Author(s) : YASHAR D. A., DOMANSKI P. A., CHO H. H.
- Date : 2011/02
- Languages : English
- Source: HVAC&R Research - vol. 17 - n. 1
View record