DAMAGES IN REFRIGERATION COMPRESSORS BECAUSE OF LIQUID SUCTION.

[In Italian. / En italien.]

Type of article: Article

Summary

AS A GENERAL RULE WITH HERMETIC AND SEMI-HERMETIC RECIPROCATING COMPRESSORS, LIQUID SUCTION IS CAUSED BY OIL FOAMING AT START-UP, OR BY EVAPORATOR OVERFEEDING. THIS PAPER ANALYSES CAUSES AND EFFECTS OF LIQUID SUCTION AND SUGGESTS SUITABLE MEASURES TO PREVENT THESE EVENTS SUCH AS LIMITATION OF REFRIGERANT CHARGE, PUMP-DOWN CYCLE, CRANKCASE HEATING AND A LIQUID RECEIVER ON THE SUCTION SIDE. E. F.

Details

  • Original title: [In Italian. / En italien.]
  • Record ID : 1990-0109
  • Languages: Italian
  • Source: Industria italiana del Freddo - vol. 43 - n. 1
  • Publication date: 1989
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (3)