DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON R600A.

Author(s) : WELSBY P., DEVOTTA S., HOLLAND F. A.

Type of article: Article

Summary

THE THEORETICAL RANKINE POWER CYCLE EFFICIENCIES AND THE PRESSURE RATIOS HAVE BEEN PRESENTED FOR RANKINE POWER CYCLES OPERATING ON R600A. THESE VALUES ARE LISTED FOR TEMPERATURE DROPS OF 10-75 K AND FOR BOILING TEMPERATURES OF 298-393 K (25-120 DEG C) IN 5 K INCREMENTS. THE DERIVED THERMODYNAMIC DATA CAN BE USED FOR THE RAPID PRELIMINARY DESIGN OF RANKINE POWER CYCLE SYSTEMS OPERATING ON R600A.

Details

  • Original title: DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON R600A.
  • Record ID : 1984-0316
  • Languages: English
  • Source: J. Heat Recov. Syst. - vol. 3 - n. 1
  • Publication date: 1983
  • Document available for consultation in the library of the IIR headquarters only.