DESIGN, CONSTRUCTION AND TESTING OF AN EXHAUST AIR HEAT PUMP FOR R-2000 HOUSES.
Author(s) : LINTON J. W.
Type of article: Periodical article
Summary
DESCRIBES THE DESIGN, CONSTRUCTION AND TESTING OF AN EXHAUST AIR HEAT PUMP-HEAT PIPE COMBINATION USED FOR VENTILATION HEAT RECOVERY OF R-2000 (TIGHTLY CONSTRUCTED) HOUSES. TWO SIZES OF HEAT PUMP WERE BUILT AND TESTED, A SMALL NON-FROSTING VERSION AND A LARGE VERSION WITH A DEFROST SYSTEM, OR EVAPORATOR PRESSURE REGULATOR TO PREVENT FROSTING. BOTH SIZES PROVIDED EXCELLENT PERFORMANCE OVER A WIDE RANGE OF OUTDOOR TEMPERATURES. THE COP RANGES FROM 2.5 AT 288 K (15 DEG C) TO 2.3 AT 248 K (-25 DEG C). (INT. BUILD. SERV. ABSTR., GB., 23, N 3, 1988, 7, 88-00727.
Details
- Original title: DESIGN, CONSTRUCTION AND TESTING OF AN EXHAUST AIR HEAT PUMP FOR R-2000 HOUSES.
- Record ID : 1989-0283
- Languages: English
- Source: NRCC-CNRC, Tech. Rep. - TR-LT-013; 37 p.; 19 fig.; 2 ref.
- Publication date: 1987/03
- Document available for consultation in the library of the IIR headquarters only.
Links
See the source
Indexing
-
Themes:
Heat pumps techniques;
Residential heat-pumps - Keywords: Heat pipe; Frosting; Exhaust air; Single-family house; Design; Heat recovery; Heat pump; Performance; Testing; COP
-
ECONOMICS, TESTING AND EVALUATION OF AN EXHAUST...
- Author(s) : LINTON J. W.
- Date : 1988
- Languages : English
View record
-
FIELD TEST ON AN EXHAUST AIR HEAT RECOVERY HEAT...
- Author(s) : CHAUHAN R. B.
- Date : 1985
- Languages : English
- Source: Build. Res. Note - n. 226
View record
-
COMPARISON OF FREEZING CONTROL STRATEGIES FOR R...
- Author(s) : PHILLIPS E. G.
- Date : 1989
- Languages : English
View record
-
DOMESTIC VENTILATION UNIT WITH HEAT EXCHANGER A...
- Author(s) : MCINTYRE D. A.
- Date : 1989
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 10 - n. 1
View record
-
FIELD-MEASURED CYCLING, FROSTING AND DEFROSTING...
- Author(s) : BAXTER V. D., MOYERS J. C.
- Date : 1985
- Languages : English
View record