Determination of the pressurizing period for stored cryogenic fluids.
Author(s) : HOFMANN A.
Type of article: Article
Summary
It is a normal operating condition for a lot of cryogenic storage vessels that no boil-off gas is vented over long periods, which leads to a simultaneous pressure increase of the stored fluid. One main reason therefore is to avoid product losses during transport or between withdrawals. At transport conditions the mixing of the fluid can be assumed to be ideally, which results in a maximum reachable pressurizing period. At stationary conditions the pressurizing period is expected to be shorter, because a stratification is rising up, so that the heat capacity of the stored fluid cannot be used completely. In a thermodynamic view, an isochore change of state takes place and the heat flux into the vessel rises the internal energy of the fluid. For the representation of the isochore change of state a new developed-diagram is introduced. The basis line is linear for the filling rate and functionally connected with the specific volume. For the fluids He and H2 e.g., diagrams are pointed out, using the u- and v-values on the saturation lines for the two phase region and those of some isobar lines for the region above the critical pressure. [Reprinted with permission from Elsevier. Copyright, 2006].
Details
- Original title: Determination of the pressurizing period for stored cryogenic fluids.
- Record ID : 2007-0940
- Languages: English
- Source: Cryogenics - vol. 46 - n. 11
- Publication date: 2006/11
Links
See other articles in this issue (5)
See the source
Indexing
-
Problems of practical use of thermoacoustics un...
- Author(s) : KUZMINA A. G., GORBACHEV S. P.
- Date : 1991/10
- Languages : English
- Source: Cryogenics - vol. 31 - n. 10
View record
-
HEAT TRANSFER IN FLOATING INSULATIONS FOR OPEN ...
- Author(s) : SRINIVASA MURTHY S., KRISHNA MURTHY M. V.
- Date : 1981
- Languages : English
- Source: Cryogenics - vol. 21 - n. 11
View record
-
TWO-PHASE TRANSFER LIQUID NITROGEN COOLER FOR R...
- Author(s) : CHEN Y. C., LI Y. S.
- Date : 1983/12
- Languages : Chinese
- Source: J. chin. Assoc. Refrig. - n. 4
View record
-
CYLINDER VALVE CONTROLLER FOR AN UNINTERRUPTED ...
- Author(s) : ULVICK L. M., EVELYN M. P. d'
- Date : 1990
- Languages : English
- Source: Rev. sci. Instrum. - vol. 61 - n. 12
View record
-
APPLICATIONS OF CRYOGENIC CONTAINERS.
- Author(s) : TANTAM D.
- Date : 1981
- Languages : English
- Source: Cryogenics - vol. 21 - n. 12
View record