Summary
THE INFRARED SPACE OBSERVATORY CRYOSTAT WAS DEFINED AS A HYBRID COOLING SYSTEM USING LIQUID HYDROGEN AND SUPERFLUID HELIUM. A DIRECTLY ELECTRICALLY OPERATED BISTABLE LATCH-VALVE WAS DEVELOPED AND PREQUALIFICATION TESTED FOR APPLICATION WITHIN THE H2 SUBSYSTEM AND THE HELIUM II SBYTM THIS VALVE IS OPERABLE BETWEEN 1.7 AND 300 K AND WITH H2 AND HELIUM IN ALL PHASES (LIQUID, SUPERFLUID, GASEOUS). IT OFFERS VERY HIGH LEAK TIGHTNESS AT HIGHER TEMPERATURES AND SUFFICIENT LEAK-TIGHTNESS EVEN WITH HELIUM II.
Details
- Original title: DIRECTLY OPERATED VALVE FOR SPACE CRYOSTATS.
- Record ID : 1987-1667
- Languages: English
- Source: Cryogenics - vol. 27 - n. 1
- Publication date: 1987
Links
See other articles in this issue (5)
See the source
-
A VERSATILE METALLIC LIQUID HELIUM CRYOSTAT.
- Author(s) : SUNDARAM S., CHANDRA G.
- Date : 1983
- Languages : English
- Source: Indian J. Cryog. - vol. 8 - n. 4
View record
-
LIQUID HELIUM COOLED SAMPLE STAGE FOR SCANNING ...
- Author(s) : SEIFERT H.
- Date : 1982
- Languages : English
- Source: Cryogenics - vol. 22 - n. 12
View record
-
An absolute cryogenic calibration source for a ...
- Author(s) : GERVASI M., BONELLI G., SIRONI G., CAVALIERE F., PASSERINI A., CASANI S.
- Date : 1995/10
- Languages : English
- Source: Rev. sci. Instrum. - vol. 66 - n. 10
View record
-
COMBINATION CLOSED-CYCLE REFRIGERATOR/LIQUID HE...
- Author(s) : JOHNSON E. C.
- Date : 1987
- Languages : English
- Source: Rev. sci. Instrum. - vol. 58 - n. 12
View record
-
HIGH-PERFORMANCE, 2.5 K CRYOSTAT INCORPORATING ...
- Author(s) : ARCHER J. W.
- Date : 1985
- Languages : English
- Source: Rev. sci. Instrum. - vol. 56 - n. 3
View record