Domestic ventilation rates, indoor humidity and dust mite allergens: are our homes causing the asthma pandemic?

Author(s) : HOWIESON S. G., LAWSON A., MCSHARRY C., et al.

Type of article: Article

Summary

This article is concerned with historical changes in domestic ventilation rates, relative humidity and the associated risk of house dust mite colonization. A controlled trial evaluated allergen and water vapour control measures on the level of house dust mite (HDM) Der p1 allergen and indoor humidity, concurrently with changes in lung function in 54 subjects who completed the protocol. Mechanical heat recovery ventilation units significantly reduced moisture content in the active group, while HDM allergen reservoirs in carpets and beds were reduced by circa 96%. Self reported health status confirmed a significant clinical improvement in the active group. The study can form the basis for assessing minimum winter ventilation rates that can suppress RH below the critical ambient equilibrium humidity of 60% and thus inhibit dust mite colonization and activity in temperate and maritime influenced climatic regions.

Details

  • Original title: Domestic ventilation rates, indoor humidity and dust mite allergens: are our homes causing the asthma pandemic?
  • Record ID : 2004-2932
  • Languages: English
  • Source: Build. Serv. Eng. Res. Technol. - vol. 24 - n. 3
  • Publication date: 2003/10
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (3)
See the source