Summary
This paper outlines the influence of heat pump systems on energy consumption for heating/cooling for a non-residential building located in Bucharest, Romania. The analysis refers to a geothermal heat-pump, consisting of a vertical borehole heat exchanger, coupled to a radiant heat floor system designed for a non-residential building. The thermal behavior of the heat pump system is described by means of a computer model developed under TRNSYS software. The numerical data obtained by simulations were compared with experimental data acquired on the building analyzed. The two sets of results showed good agreement. Starting from the validated model, a computer model was created and a series of simulations were performed consequently. These simulations followed the variation of the heat energy demand, energy consumption of the whole system and the variation of the performance coefficient of the heat pump system for heating and cooling. The evaluation of the results obtained from the simulations will enable both the creation of viable solutions regarding the evaluation of heat pump energy consumption and the development of the study regarding the possibility of implementing these systems for exploitation of renewable energy.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Energy evaluation of a geothermal heat-pump system for a non-residential building.
- Record ID : 30008675
- Languages: English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Publication date: 2013/06/16
Links
See other articles from the proceedings (424)
See the conference proceedings
Indexing
-
Themes:
Heat pumps techniques;
Comfort air conditioning - Keywords: Radiation; Geothermy; Floor; Cooling; Ground; Heat pump; Heating
-
Multi-variable optimization of HVAC system usin...
- Author(s) : LI R., OOKA R.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Energy and comfort performance analysis of moni...
- Author(s) : GANTIEZ C., LEMORT V., HOOGMARTENS J., et al.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record
-
Simulation of the energy performance of a GEOTA...
- Author(s) : PARYS W., HOOGMARTENS J., HELSEN L., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
A discussion on a new structure of low temperat...
- Author(s) : MU W., WANG S., TIAN X.
- Date : 2007/07/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Wspólpraca zintegrowanego ukladu grzewczo-chlod...
- Author(s) : BASINSKA M., KRZYZANIAK G.
- Date : 2008/10/15
- Languages : Polish
- Source: Projektowanie i eksploatacja przyjaznych srodowisku systemów chlodniczych i klimatyzacyjnych. Miedzynarodowa konferencja. XL Dni chlodnictwa.
- Formats : PDF
View record