ENHANCED HEAT TRANSFER FROM A HORIZONTAL FINNED TUBE SITUATED IN A VERTICAL CHANNEL.

Author(s) : SPARROW E. M.

Type of article: Article

Summary

THE RESPONSE OF THE FINNED-TUBE HEAT TRANSFER TO THREE GEOMETRIC PARAMETERS WAS INVESTIGATED: (1) THE VERTICAL POSITION OF THE TUBE IN THE CHANNEL, (2) THE CLEARANCE BETWEEN THE FIN TIPS AND THE CHANNEL WALLS, AND (3) THE HEIGHT OF THE CHANNEL. EXPERIMENTS WERE ALSO CARRIED OUT WITH THE FINNED TUBE SITUATED IN FREE SPACE. IN-CHANNEL POSITIONING GAVE RISE TO SUBSTANTIALLY HIGHER HEAT TRANSFER RATES THAN DID FREE-SPACE POSITIONING. WITH THE FINNED TUBE SITUATED IN THE CHANNEL, THE HEAT TRANSFER WAS ENHANCED BY: (1) POSITIONING THE TUBE AT THE BOTTOM OF THE CHANNEL, (2) SMALL TIP-TO-WALL CLEARANCES, AND (3) TALL CHANNELS.