EXERGY MAXIMIZATION IN REFRIGERATION STORAGE UNITS WITH HEAT LEAK.

Author(s) : SAHOO R. K.

Type of article: Article

Summary

THE PAPER PRESENTS SECOND LAW OF THERMODYNAMICS ANALYSIS TECHNIQUES FOR SENSIBLE REFRIGERATION ENERGY STORAGE UNITS WITH NON-ADIABATIC BOUNDARIES. THE INVESTIGATION IS BASEDON THE MINIMIZATION OF ENTROPY PRODUCTION DUE TO A FINITE TEMPERATURE DIFFERENCE. THE RESULTS OF THE STUDY INDICATE 3 BASIC POINTS: 1) IN THE PRESENCE OF HEAT LEAKS, THE IRREVERSIBILITY RATE IS MORE THAN IN ITS ABSENCE ; 2) THE INCREASEIN IRREVERSIBILITY DUE TO HEAT LEAKS REDUCES THE EFFECTIVE NUMBER OF TRANSFER UNITS EXPONENTIALLY ; AND 3) THERE EXISTS A DIMENSIONLESS OPTIMUM TIME PARAMETER WHICH RELATES 2 OTHER FUNDAMENTAL DIMENSIONLESS PARAMETERS FOR THE MAXIMIZATION OF USEFUL WORK STORED.

Details

  • Original title: EXERGY MAXIMIZATION IN REFRIGERATION STORAGE UNITS WITH HEAT LEAK.
  • Record ID : 1990-2269
  • Languages: English
  • Source: Cryogenics - vol. 29 - n. 1,1989.01
  • Publication date: 1989