IIR document

Experimental and numerical investigation of a high-effectiveness cryogenic PCHE for space 80 K Brayton cryocooler.

Author(s) : ZHANG Z., CHEN L., LV H., LI S., HOU Y.

Type of article: IJR article

Summary

Growing space cooling demand has made reverse Brayton cryocooler a promising technology, requiring higher effectiveness and lighter weight recuperative heat exchangers. This study proposes a novel cryogenic printed circuit heat exchanger (PCHE) design for an 80 K space Brayton cryocooler, with both high thermal performance and compactness. Unlike conventional PCHEs, the proposed cryogenic PCHE features high-density micro-fins (114 cm-2) and a thin wall (wall thickness of 0.1 mm), achieving a compactness of 4548 m2⋅m-3, 82 % higher than conventional designs. A counter-flow heat transfer model is developed, incorporating axial heat conduction effects typically overlooked in PCHE design models. Through systematic optimization, the cryogenic PCHE achieves a heat duty of 2.2 kW for gas neon between 80 K and 313 K, with compact core dimensions of 460 mm × 86 mm × 82 mm. Experimental testing demonstrated the exceptional performance of the cryogenic PCHE, achieving a heat transfer effectiveness of 97.3 %, surpassing conventional PCHEs, with only a 7.6 kPa total pressure drop. Compared to conventional plate-fin heat exchangers (PFHE) used in ground Brayton  ryocoolers, the cryogenic PCHE shows superior performance. This design achieves a performance evaluation criterion of 1.8, while reducing 80 % volume requirements at equivalent thermal effectiveness. Additionally, the analysis reveals a 1.2 % effectiveness deterioration due to axial conduction, which leads to an 87.4 % overestimation of the
cryocooler’s cooling capacity, highlighting its significance in high-effectiveness cryogenic heat exchanger design. 

Available documents

Format PDF

Pages: 14 p.

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental and numerical investigation of a high-effectiveness cryogenic PCHE for space 80 K Brayton cryocooler.
  • Record ID : 30034279
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 176
  • Publication date: 2025/08
  • DOI: http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2025.04.013

Links


See other articles in this issue (30)
See the source

Indexing

  • Themes: N/A
  • Keywords: N/A