IIR document
Experimental determination of the optimum performance of ejector refrigeration system depending on ejector area ratio.
Author(s) : YAPICI R., ERSOY H. K., AKTOPRAKOGLU A., et al.
Type of article: Article, IJR article
Summary
The performance of the ejector refrigeration system using ejectors with cylindrical mixing chamber is studied at operating conditions with choking in the mixing chamber. The condenser pressure is chosen so that the secondary flow choking can occur even in the ejector with the smallest area ratio. In this study, the performance of the constructed system is determined by using six configurations of ejector and R123 as working fluid in the system. The study is performed over a range of the ejector area ratio from 6.5 to 11.5 at the compression ratio 2.47. In the studied range, the experimental coefficient of performance of the system rises from 0.29 to 0.41, as the optimum generator temperature increases from 83 to 103 °C. Similar results were also found in the parametric study when the efficiencies of the nozzle and diffuser are taken as 0.90.
Available documents
Format PDF
Pages: 1183-1189
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental determination of the optimum performance of ejector refrigeration system depending on ejector area ratio.
- Record ID : 2008-4000
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 7
- Publication date: 2008/11
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (18)
See the source
Indexing
-
Effect of throat diameters of the ejector on th...
- Author(s) : CHAIWONGSA P., WONGWISES S.
- Date : 2007/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 4
- Formats : PDF
View record
-
Numerical investigation of geometry parameters ...
- Author(s) : ZHU Y., CAI W., WEN C., et al.
- Date : 2009/01
- Languages : English
- Source: Applied Thermal Engineering - vol. 29 - n. 1
View record
-
The effect of operating conditions on the perfo...
- Author(s) : AIDOUN Z., OUZZANE M.
- Date : 2004/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 27 - n. 8
- Formats : PDF
View record
-
Comparison of experimental and calculated param...
- Author(s) : PETRENKO V. A., VOLOVIK A. S.
- Date : 2006
- Languages : Russian
- Source: Holodil'na Tehnika i Tehnologiâ - n. 6
View record
-
Geometric parameter optimization of ejector-exp...
- Author(s) : SARKAR J.
- Date : 2009
- Languages : English
- Source: Int. J. Energy Res. - vol. 34 - n. 1
View record