Summary
This paper performs a comprehensive experimental and modelling study to examine the dynamic behaviour of an upright freezer with adjustable shelving under periodic door opening conditions with different temperature, pressure and relative humidity values. An uncertainty analysis is carried out for the experimentally measured data. Additionally, the dynamic model is developed with crucial sub-components, such as discretized upright cabinet, frosted evaporator and semi-empirical door opening mechanism using an object-orientated programming language called Modelica. The present model is the validated with experimental data employing the values of the airflow from ambient into the cabinet along with the average cabinet air flowrate and back wall temperatures, transient evaporation and condensation pressures, cabinet average relative humidity change, compressor operation time and power consumption, and finally total energy consumption of refrigerator for both 85%RH and 65% RH conditions at 32 °C ambient. The results show that the model predictions have a similar trendline with the experimental findings within ±3 K error bands regarding average cabinet air and back wall temperature. In contrast, the dynamic cyclic trend before and after door opening is closer to the experiments within ±1 K. The current model predictions for the low and high pressures are found to be within ±3% and ±5% error bands, respectively, whereas the average relative humidity level of the cabinet is captured within ±10% deviation. Furthermore, transient compressor power is well predicted with deviations, but not exceeding 4.5%, and the total energy consumption level is compatible with 6% error bands during the entire experimental period.
Available documents
Format PDF
Pages: 356-369
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental investigation and dynamic modelling of an upright freezer under periodic door opening conditions.
- Record ID : 30031981
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 153
- Publication date: 2023/09
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2023.06.004
Links
See other articles in this issue (32)
See the source
-
Performance comparison with effect of door open...
- Author(s) : LIU D. Y., CHANG W. R., LIN J. Y.
- Date : 2004/10
- Languages : English
- Source: Applied Thermal Engineering - vol. 24 - n. 14-15
View record
-
Evaluación energética de un refrigerador de tip...
- Author(s) : GALICIA ROSAS C. A., MERLÍN SORIA L. A., OCADIZ R. A., et al.
- Date : 2016/05/03
- Languages : Spanish
- Source: CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
View record
-
Energy requirements of refrigerators due to doo...
- Author(s) : TERRELL W. Jr
- Date : 2006/07/17
- Languages : English
- Source: 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
View record
-
The temperature performance of domestic refrige...
- Author(s) : JAMES S. J., EVANS J.
- Date : 1992
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 15 - n. 5
- Formats : PDF
View record
-
Peering into the cabinet: quantifying the energ...
- Author(s) : HARRINGTON L., AYE L., FULLER B., et al.
- Date : 2019/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
View record