Summary
As a new passive cooling technology, space radiation cooling has great potential for development because the cooling itself has no energy consumption, and the radiation heat exchanger does not affect the appearance, with low noise and low cost. Several rectangular stainless steel plates coated with RLHY-2 material are used as the transmitter for the field test. The experimental results show that, in the case of no windscreen, the increase of outdoor humidity will reduce the cooling effect, and the greater the humidity, the more pronounced the reduction effect. Significantly when the humidity increases from 78% to 90%, the cooling power of the cooler reduces from 102 to 67 W/m2. The thickness of the cloud layer also affects the cooling effect of the space radiative cooler. Compared with the clear weather, the cooling power of the cooler is reduced by 11.65 W/m2 on average under foggy weather conditions. Compared with the force-1 wind and the force-3 wind, the cooling effect of the cooler is the worst under the condition of the force-2 wind, and the average cooling power is only 49.76 W/m2. In addition, laying polyethylene (PE) film as a windscreen is beneficial to improving the radiative cooling effect, and the difference in surface temperature between the two is up to 3 °C. This research provides a theoretical basis and practical reference for applying radiative cooling technology in different regions and seasons and adjusting and improving its effects.
Available documents
Format PDF
Pages: 18 p.
Available
Free
Details
- Original title: Experimental Study on the Performance of a Space Radiation Cooling System under Different Environmental Factors.
- Record ID : 30030593
- Languages: English
- Subject: Technology
- Source: Energies - vol. 15 - n. 19
- Publishers: MDPI
- Publication date: 2022/10
- DOI: http://dx.doi.org/10.3390/en15197404
Links
See other articles in this issue (13)
See the source
Indexing
- Themes: Comfort air conditioning
- Keywords: Radiation; Passive cooling; Outdoor environment; Expérimentation; Performance; Roof; Humidity; Radiative cooling
-
Analysis of a cool roof system for reducing coo...
- Author(s) : PISELLO A. L., THIEMANN A., SANTAMOURIS M., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Thermal environment of the low-exergy system co...
- Author(s) : TAKAHASHI I., TSUJII Y., ITOU N.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Discussion on condensation in a radiant cooling...
- Author(s) : HE J., SHEN J., SHOU Q., et al.
- Date : 2008/06
- Languages : Chinese
- Source: HV & AC - vol. 38 - n. 6
- Formats : PDF
View record
-
Free subcooling with the sky: Improving the eff...
- Author(s) : GOLDSTEIN E., NASUTA D., LI S., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Performance enhancement of an air-conditioning ...
- Author(s) : NGUYEN V., MEHRI R., GODBOUT G., MATIDA E.
- Date : 2020/09
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 117
- Formats : PDF
View record