Summary
According to the characteristics of climate variability all over the country, establishes the six-district model with the evaporative cooling technology suited to different regions. Analyses the application modes of direct evaporation and indirect evaporation technology in different regions. Builds the test bed of the evaporative cooling air conditioning which can simulate the outdoor environment in different regions for the experimental measurements and compares with the theory studying. The results show that the application form of the evaporative cooling technology in six-district is broadly consistent with the theory; that the measured value of the air temperature is lower than the theory value and the cooling effect is better; and that it can meet the requirements of air conditioning supply air with the direct evaporative cooling when the outdoor design wet-bulb temperature for summer air conditioning is below 16°C.
Available documents
Format PDF
Pages: 78-81, 54
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30013565
- Languages: Chinese
- Source: HV & AC - vol. 44 - n. 289
- Publication date: 2014/04
Links
See other articles in this issue (1)
See the source
Indexing
- Themes: Humidification/dehumidification equipment
- Keywords: Comparison; China; Performance; Evaporative system; Model; Air conditioning
-
Desiccant cooling: an economic comparison of th...
- Author(s) : GÖBEL U.
- Date : 1994/11/16
- Languages : German
- Source: DKV-Tagungsbericht 1994 Bonn.
View record
-
Performance analysis of different air condition...
- Author(s) : WANG H., LIU L., CHENG Q.
- Date : 2022/07
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 139
- Formats : PDF
View record
-
Performance comparison of waste heat-driven des...
- Author(s) : COWIE M., LIAO X., RADERMACHER R.
- Date : 2003
- Languages : English
- Source: ASHRAE Transactions. 2003 annual Meeting, Kansas City, Missouri, USA. Volume 109, part 2 + CD-ROM.
View record
-
Annual performance of liquid desiccant based in...
- Author(s) : LIU X., LI Z., JIANG Y., et al.
- Date : 2006/08
- Languages : English
- Source: Applied Thermal Engineering - vol. 26 - n. 11-12
View record
-
Performance analysis of a no-frost hybrid air c...
- Author(s) : ZHANG L., DANG C., HIHARA E.
- Date : 2010/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 1
- Formats : PDF
View record