EXPLORATORY STUDY ON THE AVOIDING OF COLD BATTERIES ICING BY MEANS OF LOW FREEZING POINT FLUID SPRAYING.

ETUDE EXPLORATOIRE SUR L'ELIMINATION DU GIVRAGE DES BATTERIES FROIDES PAR ASPERSION AVEC UN FLUIDE A BAS POINT DE CONGELATION.

Author(s) : PATUREAU J. P.

Type of article: Periodical article

Summary

TEST RESULTS OF A 5 HP DOMESTIC EXTERNAL AIR/WATER HEAT PUMP HAVE SHOWN THE FOLLOWING. THE MECHANICAL FROST REMOVAL WITH A NON RECOVERABLE FLUID (SILICON OIL OF THE TYPE RHODORSIL 47 V20) APPEARS TO BE DIFFICULT AND UNCERTAIN. FROST ABSORPTION BY A HYDROPHILE SOLUTION OF LITHIUM CHLORIDE APPEARS TO BE MORE PROMISING. THE NEED OF CONTINUOUS REGENERATION OF THE SOLUTION (BY A BOILER WITH MECHANICAL VAPOUR RECOMPRESSION) REQUIRES ADDITIONAL INVESTMENT AND OPERATING COSTS JUSTIFIED ONLY FOR BIG INSTALLATIONS. (Bibliogr. int. IFP-CNRS, FR., 84-T230-8252.

Details

  • Original title: ETUDE EXPLORATOIRE SUR L'ELIMINATION DU GIVRAGE DES BATTERIES FROIDES PAR ASPERSION AVEC UN FLUIDE A BAS POINT DE CONGELATION.
  • Record ID : 1984-1859
  • Languages: French
  • Source: DGRST - 80.7.0023; 67 p.
  • Publication date: 1982

Links


See the source