Defining the required trackability level of the target condition for the testing facility reconditioning unit represents an unresolved challenge in improving the reproducibility of load-based tests and corresponding performance rating standards development. To enhance the reproducibility of such testing methodology, this paper presents and discusses a new feed-forward compensation technique based on the development of a transfer function model for the delay and offset characteristics of the psychrometric room's air temperature and humidity modulations with reference to the target signal from the room emulator. It is demonstrated that the proposed methodology enables offset and delay reduction in the trackability of the return air condition within 60 s at different testing conditions, enhances the reproducibility of the test results to limit performance deviations to within 2 %, and achieves closely matched controlled parameter modulations during load-based tests.
Available documents
Format PDF
Pages: 257-268
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Feed-forward compensation for emulator-type testing facilities.
- Record ID : 30032806
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 167
- Publication date: 2024/11
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2024.07.023
Links
See other articles in this issue (22)
See the source
Indexing
- Themes: Comfort air conditioning
- Keywords: Control (generic); Temperature; Modelling; Expérimentation; Testing; Air conditioning
-
A temperature humidity independent control air-...
- Author(s) : LIU C., ZHANG X.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
A museum storeroom air-conditioning system empl...
- Author(s) : ZHANG X. J., YU C. Y., LI S., et al.
- Date : 2011/12
- Languages : English
- Source: Applied Thermal Engineering - vol. 31 - n. 17-18
View record
-
NON-LINEAR DYNAMIC CONTROLLER FOR AIR CONDITION...
- Author(s) : DAMIANI G., DUMAS A., SARTI E.
- Date : 1989/03
- Languages : Italian
- Source: Cond. Aria - vol. 33 - n. 3
View record
-
A state space modeling approach and subspace id...
- Author(s) : HU J., KARAVA P.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record
-
Experimental investigation on a novel temperatu...
- Author(s) : JIANG Y., GE T. S., WANG R. Z., et al.
- Date : 2014/12
- Languages : English
- Source: Applied Thermal Engineering - vol. 73 - n. 1
View record