HELIUM 4 ISOTOPIC PURIFICATION WITHOUT A SUPERLEAK.
Author(s) : JEWELL C. I., GOLUB R., MCCLINTOCK P. V. E.
Type of article: Article
Summary
THE AUTHORS REPORT THE SUCCESSFUL OPERATION OF A HELIUM 4 ISOTOPIC PURIFICATION CRYOSTAT WHICH DEPENDS FOR ITS OPERATION SOLELY ON THE PHENOMENON OF SUPERFLUID HEAT FLUSH. THE PRODUCT HELIUM 3 CONTENT WAS DETERMINED AS BEING LESS THAN 3 X 10 POWER -11.
Details
- Original title: HELIUM 4 ISOTOPIC PURIFICATION WITHOUT A SUPERLEAK.
- Record ID : 1983-0841
- Languages: English
- Source: Cryogenics - vol. 22 - n. 7
- Publication date: 1982
Links
See other articles in this issue (4)
See the source
Indexing
- Themes: Transport and handling of cryogenic fluids
- Keywords: Superfluidity; Cryostat; Superfluid helium
-