Summary
With the availability of the many energy efficient technologies, significant reduction in energy consumption can be expected through retrofit of existing buildings. To achieve a cost-effective retrofit, however, a good understanding of the building system is necessary. In this study, two office buildings under retrofit in the Philadelphia area have been evaluated based on measured data and simulation outputs. The results showed that even with limited data points available, some inefficient operations and designs could be identified when combined with simulation of the integrated building systems. Thermal comfort could also be improved with appropriate redesign or controls of the buildings evaluated. By incorporating the hard constraints of the existing systems, the corresponding retrofit measures can be more cost effective. A sensitivity analysis of some key design and operation parameters provided further potential energy savings with relaxed system constraints.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Informed building retrofit based on simulation and data analysis.
- Record ID : 30013791
- Languages: English
- Subject: Environment
- Source: 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Publication date: 2014/07/14
Links
See other articles from the proceedings (66)
See the conference proceedings
Indexing
-
Themes:
Comfort air conditioning;
Green buildings - Keywords: Office; Energy consumption; Building; Design; Simulation; Energy saving; Retrofitting; Thermal comfort
-
Energy consumption indicator for office buildings.
- Date : 1995
- Languages : Dutch
- Source: ISSO - n. 37
View record
-
STUDY ON THERMAL COMFORT OF A LOW-PARTITION AIR...
- Author(s) : NAKAMURA Y.
- Date : 1990
- Languages : English
View record
-
OFFICE BUILDING WITH OPTIMIZED ENERGY CONSUMPTI...
- Date : 1982
- Languages : German
- Source: Sanit. Heiz.tech. - vol. 47 - n. 3
View record
-
IMPROVING ENERGY UTILIZATION EFFICIENCY THROUGH...
- Author(s) : PARKER J.
- Date : 1987
- Languages : English
- Source: Encontro nac. Refrig. Ar cond., ENRAC, Lisbonne - 1987.05.19-21; 7 p.; 2 fig.
View record
-
Development of a façade retrofit performance gu...
- Author(s) : SHEN H., CHAN Y-C., TZEMPELIKOS A.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record