Summary
To analyze the influence of liquid spraying flow rate on the performance of a falling-film evaporator with R134a, the finite difference model of the horizontal-tube falling-film evaporator is established, and a falling-film air-cooled water chiller with ejector liquid recirculation system (LRS) is presented; then the comparison between numerical simulation and experimental tests are performed. The analysis results show that the experimental and numerical evaporating capacities increase 9.5% and 6.7%, respectively, when the liquid recirculating ratio Rl increases from 1.0 to 1.21; and the deviation between the experimental and numerical capacities of the evaporator is about 3.3%. And that the evaporated liquid flow rate rises quickly at first and then increases slightly as Rl increases. Moreover, the results show that the optimum value of Rl is about 1.2, the corresponding value of integrated falling-film factor f with about 0.85. This suggests that attempting to eliminate completely the dryout patch outside of tubes is unadvisable.
Available documents
Format PDF
Pages: 331-342
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Investigation on the effect of ejector liquid recirculation system on the performance of falling-film water chiller with R134a.
- Record ID : 30020113
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Publication date: 2017/02
Links
See other articles in this issue (56)
See the source
Indexing
-
Experimental evaluation of an ejector as liquid...
- Author(s) : LI Y. L., TAN L., ZHANG X., et al.
- Date : 2014/04
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
View record
-
Study on the effect of refrigerant distributing...
- Author(s) : LI Y., WANG K., WU W., et al.
- Date : 2017/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Formats : PDF
View record
-
Performance analysis of an ejector cooling syst...
- Author(s) : TIRMIZI S. A., SIDDIQUI O. K., GANDHIDASAN P., et al.
- Date : 2014/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 66 - n. 1-2
View record
-
Seasonal performance optimisation of thermally ...
- Author(s) : EXPÓSITO CARRILLO J. A., SÁNCHEZ DE LA FLOR F. J., SALMERÓN LISSEN J. M.
- Date : 2019/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
View record
-
Experimental investigations on a R134a ejector ...
- Author(s) : YAN J., CHEN G., LIU C., et al.
- Date : 2017/01/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 110
View record