Liquid-side fouling of heat exchangers. An integrated R&D approach for conventional and novel designs.

Author(s) : KARABELAS A. J., YIANTSIOS S. G., THONON B., GRILLOT J. M.

Type of article: Article

Summary

New fouling data are reported for plate heat exchangers (of two angles of corrugation, 30 and 60 deg) and particles of mean size approx. 5 micrometres. Fouling (under the test conditions) is adhesion controlled and the maximum measured resistance is almost an order of magnitude smaller than the TEMA recommendations. For a specific particle size, a distribution of adhesive strengths (rather than a single value) is obtained which is strongly influenced by pH and may be time-dependent for very small sizes. Various applications of the results are outlined.

Details

  • Original title: Liquid-side fouling of heat exchangers. An integrated R&D approach for conventional and novel designs.
  • Record ID : 1998-3432
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 17 - n. 8-10
  • Publication date: 1997/08

Links


See other articles in this issue (4)
See the source