Magnetic susceptibility of materials screened for use in fabricating a non-magnetic liquid helium dewar.
Type of article: Article
Summary
Susceptibility measurements were made at room temperature and 4.5 K for 29 substances. The results of these magnetic susceptibility measurements are reported together with the materials' use and supplier.
Details
- Original title: Magnetic susceptibility of materials screened for use in fabricating a non-magnetic liquid helium dewar.
- Record ID : 1997-0011
- Languages: English
- Source: Cryogenics - vol. 36 - n. 5
- Publication date: 1996/05
Links
See other articles in this issue (4)
See the source
Indexing
- Themes: Transport and handling of cryogenic fluids
- Keywords: Helium; Magnetic susceptibility; Material; Magnetism; Dewar; Cryogenics
-
PLASTIC DEWAR FOR PRESSURIZED SUPERFLUID HELIUM.
- Author(s) : KOBAYASHI H.
- Date : 1987
- Languages : English
- Source: Cryogenics - vol. 27 - n. 6
View record
-
PLASTIC DEWAR FOR HYBRID COOLING OF PRESSURIZED...
- Author(s) : KOBAYASHI H.
- Date : 1987
- Languages : Japanese
- Source: Cryogenics/ Cryog. Eng. - vol. 22 - n. 2
View record
-
AUTOMATIC LIQUID HELIUM TRANSFER SYSTEM.
- Author(s) : IHAS G. G., SPENCER G. F., ALEXANDER P. W.
- Date : 1982
- Languages : English
- Source: Rev. sci. Instrum. - vol. 53 - n. 9
View record
-
CHARCOAL-PUMPED HELIUM 3 CRYOSTATS FOR STORAGE ...
- Author(s) : SWARTZ E. T.
- Date : 1987
- Languages : English
- Source: Rev. sci. Instrum. - vol. 58 - n. 5
View record
-
DEWAR TO DEWAR MODEL FOR SUPERFLUID HELIUM TRAN...
- Author(s) : SNYDER H. A.
- Date : 1988
- Languages : English
- Source: Cryogenics - vol. 28 - n. 2
View record