IIR document
Mobile air conditioning fuel consumption and thermal comfort assessment procedure.
Author(s) : MALVICINO C., MOLA S., CLODIC D.
Summary
The paper describes a method proposal to assess the fuel consumption and the perceived thermal comfort level during climatic room testing. The procedure has been elaborated in the framework of the EU funded project B-COOL and constitutes one of the project outputs. The B-COOL project is focused to the development of a low cost and high efficiency CO2 mobile air-conditioning system for low segment cars. The project is carried out by a consortium constituted by the Centro Ricerche Fiat, that is the coordinator, Valeo, Delphi, Manuli, Hydro, Sintef, Armines, Braunschweig University and Ford. The procedure has been conceived as a proposal for a common method to qualify the mobile air conditioning system in terms of fuel consumption and thermal comfort so to be able to compare systems based on different approaches or technologies (e.g. CO2 vs R-134a vs R-152a).
Available documents
Format PDF
Pages: 2006-2
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Mobile air conditioning fuel consumption and thermal comfort assessment procedure.
- Record ID : 2007-1716
- Languages: English
- Source: 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Publication date: 2006/05/29
Links
See other articles from the proceedings (111)
See the conference proceedings
Indexing
- Themes: Mobile air conditioning
- Keywords: Car; Measurement; Process; Performance; Testing; Thermal comfort; Air conditioning
-
Klimakomfortmessung im Fahrzeug.
- Author(s) : MASUDA T., OGAWA K., GYÖRÖG T.
- Date : 1999/11/17
- Languages : German
- Source: DKV-Tagungsbericht 26. 1999, Berlin.
View record
-
Dynamic behaviour of mobile air-conditioning sy...
- Author(s) : GADO A., HWANG Y., RADERMACHER R.
- Date : 2008/03
- Languages : English
- Source: HVAC&R Research - vol. 14 - n. 2
View record
-
Measurement of leak flow rates of mobile air-co...
- Author(s) : CLODIC D., PALANDRE L.
- Date : 2004/04/14
- Languages : English
- Source: MAC (mobile air conditioning) Summit 2004 [CD-ROM].
View record
-
MANNEQUIN TO MEASURE THE THERMAL COMFORT IN VER...
- Author(s) : CAON S., CARUSO S., SACCHI A.
- Date : 1989/02
- Languages : Italian
- Source: Cond. Aria - vol. 33 - n. 2
View record
-
Investigation of human thermal comfort under hi...
- Author(s) : GUAN Y., HOSNI M. H., JONES B. W., et al.
- Date : 2003
- Languages : English
- Source: ASHRAE Transactions. 2003 annual Meeting, Kansas City, Missouri, USA. Volume 109, part 2 + CD-ROM.
View record