MODIFIED SEALED-TUBE METHOD FOR THE DETERMINATION OF CRITICAL TEMPERATURE.

Author(s) : MOGOLLON E., KAY W. B., TEJA A. S.

Type of article: Article

Summary

A MODIFIED SEALED-TUBE METHOD FOR THE DETERMINATION OF THE CRITICAL TEMPERATURES OF PURE FLUIDS AND FLUID MIXTURES IS DESCRIBED. CRITICAL TEMPERATURES OF TEN NORMAL ALKANES FROM N-OCTANE TO N-HEPTADECANE HAVE BEEN DETERMINED AND COMPARED WITH VALUES FOUND IN THE LITERATURE. THE METHOD IS CAPABLE OF YIELDING DATA OF HIGH PRECISION AND IS SUITABLE FOR THE STUDY OF THERMALLY UNSTABLE COMPOUNDS.

Details

  • Original title: MODIFIED SEALED-TUBE METHOD FOR THE DETERMINATION OF CRITICAL TEMPERATURE.
  • Record ID : 1983-0060
  • Languages: English
  • Source: Ind. Eng. Chem. (Fundam.) - vol. 21 - n. 2
  • Publication date: 1982
  • Document available for consultation in the library of the IIR headquarters only.