Operational test of bonded magnetocaloric plates.

Author(s) : BAHL C. R. H., NAVICKAITE K., BEZ H. N., et al.

Type of article: Article, IJR article

Summary

Bonded plates made by hot pressing La0.85Ce0.15Fe11.25Mn0.25Si1.5Hy particles and resin have been tested as active magnetic regenerators in a small scale magnetocaloric device. Firstly, the plates were carefully characterised magnetically and thermally. The plates were prepared with 5 wt% resin, and from density measurements it was found that the volume ratio of the magnetocaloric material in the plates was 0.53, due to the resin and porosity. The best operating conditions for the plate regenerator were determined at which a temperature span of 6.4 K was measured along the plates.

Available documents

Format PDF

Pages: 245-251

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Operational test of bonded magnetocaloric plates.
  • Record ID : 30022257
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 76
  • Publication date: 2017/04
  • DOI: http://dx.doi.org/10.1016/j.ijrefrig.2017.02.016

Links


See other articles in this issue (33)
See the source