Outside surface resistance: proposed new value for building design.
Author(s) : LOVEDAY D. L., TAKI A. H.
Type of article: Article
Summary
Findings of outdoor full-scale experimental studies show that the experimentally measured values for the convection coefficient are significantly higher than the values assumed in current design guidance. An expression derived from four full-scale investigations is presented. A modified design value for the external surface resistance is proposed for the condition of "normal" exposure to replace the current value of 0.06. As a result, it is recommended that the corresponding U-value for single glazing be raised to 6.3 watts/m2.K from its currently accepted value of 5.6.
Details
- Original title: Outside surface resistance: proposed new value for building design.
- Record ID : 1999-0366
- Languages: English
- Source: Build. Serv. Eng. Res. Technol. - vol. 19 - n. 1
- Publication date: 1998
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (5)
See the source
Indexing
-
Transfer function method: analisi dei metodi di...
- Author(s) : GIACONIA C., ORIOLI A.
- Date : 1999/03
- Languages : Italian
- Source: Termotecnica - vol. 53 - n. 2
View record
-
Peut-on évaluer la résistance thermique d'un mu...
- Author(s) : DIDIER G.
- Date : 1996/12
- Languages : French
- Source: Chaud Froid Plomb. - vol. 50 - n. 586
View record
-
HEAT TRANSFER ANALYSIS OF A WEST-FACING WALL.
- Author(s) : LIU W. H., WANG E. H.
- Date : 1988
- Languages : English
- Source: Appl. Energy - vol. 31 - n. 1
View record
-
Transfer function method : analisi delle basi t...
- Author(s) : GIACONIA C., ORIOLI A.
- Date : 1997/05
- Languages : Italian
- Source: Termotecnica - vol. 51 - n. 4
View record
-
DETERMINATION OF THE OVERALL HEAT TRANSFER COEF...
- Author(s) : BERKOZ E., YILMAZ Z.
- Date : 1987
- Languages : English
- Source: Archit. Sci. Rev. - vol. 30 - n. 4
View record