Outside surface resistance: proposed new value for building design.

Author(s) : LOVEDAY D. L., TAKI A. H.

Type of article: Article

Summary

Findings of outdoor full-scale experimental studies show that the experimentally measured values for the convection coefficient are significantly higher than the values assumed in current design guidance. An expression derived from four full-scale investigations is presented. A modified design value for the external surface resistance is proposed for the condition of "normal" exposure to replace the current value of 0.06. As a result, it is recommended that the corresponding U-value for single glazing be raised to 6.3 watts/m2.K from its currently accepted value of 5.6.

Details

  • Original title: Outside surface resistance: proposed new value for building design.
  • Record ID : 1999-0366
  • Languages: English
  • Source: Build. Serv. Eng. Res. Technol. - vol. 19 - n. 1
  • Publication date: 1998
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (5)
See the source