Performance analysis of a single-stage four-bed metal hydride cooling system. C. Influence of combined heat and mass recovery.

Author(s) : ABRAHAM K., PRAKASH MAIYA M., SRINIVASA MURTHY S.

Type of article: Article

Summary

The effects of combined heat and mass recovery on the performance of a single stage multi-bed metal hydride cooling system is studied. A combined recovery cycle which effectively utilizes the advantages of both heat recovery and mass recovery is described. Reduction in sensible heating and cooling requirements along with increased hydrogen desorption results in improvement of COP. Operating temperatures exert a significant influence on the performance of combined recovery cycle. It is found that combined recovery is more effective at lower heat source temperatures and also at higher intermediate temperatures.

Details

  • Original title: Performance analysis of a single-stage four-bed metal hydride cooling system. C. Influence of combined heat and mass recovery.
  • Record ID : 2005-0171
  • Languages: English
  • Source: International Journal of thermal Sciences - vol. 42 - n. 11
  • Publication date: 2003/11