Performance evaluation of a reciprocating chiller using experimental data and model predictions for fault detection and diagnosis.
Author(s) : CASTRO N. S.
Summary
This collection of 115 papers presented at the ASHRAE 2002 Winter Meeting, held in Atlantic City, NJ, USA, on January 12 to 16, 2002, includes the complete collection of symposium and technical papers as well as discussion questions and answers for every paper. Topics: air-to-carbon dioxide gas cooling heat exchangers; approaches to evaluating fenestration; backdrafting and depressurization: test methods, field measurement, and impact; characterizing the performance of desiccant systems; methods and effects of improving efficiency of unitary equipment to meet new energy efficiency requirements; solutions to low delta-T in primary-secondary pumping systems; advances in commercial refrigeration; results of smoke management research; tools and techniques for calibration of component models; absorption/sorption heat pumps and refrigeration systems; advances in refrigeration technology; HVAC diagnostics: development to implementation; commercial ground-source heat pump system challenges; kitchen ventilation system performance; application of CFD modelling to indoor airflow design problems; combined heat and power technologies for the 21st century; thermal storage performance evaluation.
Details
- Original title: Performance evaluation of a reciprocating chiller using experimental data and model predictions for fault detection and diagnosis.
- Record ID : 2003-1516
- Languages: English
- Source: ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
- Publication date: 2002/01/12
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (73)
See the conference proceedings
Indexing
-
Themes:
Other air-conditioning equipment;
Chillers - Keywords: Operation; Chiller; Anomaly; Performance; Detection; Air conditioning; Chilled water; Reciprocating compressor
-
The sensitivity of chiller performance to commo...
- Author(s) : COMSTOCK M. C., BRAUN J. E., GROLL E. A.
- Date : 2001/07
- Languages : English
- Source: HVAC&R Research - vol. 7 - n. 3
View record
-
Application of classification functions to chil...
- Author(s) : STYLIANOU M.
- Date : 1997
- Languages : English
- Source: ASHRAE Transactions.
View record
-
Fault detection and diagnosis in chillers. Mode...
- Author(s) : MCINTOSH I. B. D., MITCHELL J. W., BECKMAN W. A.
- Date : 2000/06/24
- Languages : English
- Source: ASHRAE Transactions. 2000 ASHRAE Annual Meeting, Minneapolis, Minnesota + CD-ROM.
View record
-
A survey of common faults for chillers.
- Author(s) : COMSTOCK M. C., BRAUN J. E., GROLL E. A.
- Date : 2002/01/12
- Languages : English
- Source: ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
View record
-
Performance factors as a basis of practical fau...
- Author(s) : KÄRKI S. H., KARJALAINEN S. J.
- Date : 1999
- Languages : English
- Source: ASHRAE Transactions. 1999 Winter Meeting, Chicago, Illinois + CD-ROM.
View record