Summary
A regenerative Ericsson refrigeration cycle using electrocaloric (EC) materials as the working medium is established. In accordance with the thermodynamic properties of EC materials, the mathematical expressions of the coefficient of performance (COP) and cooling rate of the regenerative EC Ericsson refrigeration cycle are derived. The cooling rate is selected as an objective function and optimized with respect to one of the two isothermal process temperatures in the Ericsson refrigeration cycle, Subsequently, the optimal ranges and bounds of the COP and dimensionless cooling rate are determined. Furthermore, the impacts of the heat leakage, finite heat capacities of heat reservoirs at high and low temperature sides, the Curie temperature of EC materials, the electric field intensity difference in the EC Ericsson refrigeration as well as the regenerator efficiency, internal irreversibility resulting from the thermal hysteresis of EC materials, etc. on the optimal performance of the regenerative EC Ericsson refrigeration cycle are revealed. The conclusions obtained are beneficial to the optimal parameter design of EC refrigerators.
Available documents
Format PDF
Pages: 197-205
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance optimization on the irreversible regenerative Ericsson refrigeration cycle using electrocaloric materials as the working medium.
- Record ID : 30029623
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 138
- Publication date: 2022/06
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2022.03.016
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (20)
See the source
Indexing
-
Themes:
Caloric cooling (magnetocaloric, electrocaloric, elastocaloric and barocaloric cooling);
Ejector systems, air cycle, Stirling cycle, other cycles) - Keywords: Performance; Optimization; Electrocaloric cooling; Material; Ericsson; Thermodynamic property; Modelling; Thermodynamic cycle; Calculation
-
Cost optimization of a dual Halbach cylinder ma...
- Author(s) : TURA A., ROWE A.
- Date : 2012/09/17
- Languages : English
- Source: 5th International Conference on Magnetic Refrigeration at Room Temperature (Thermag V). Proceedings: Grenoble, France, September 17-20, 2012.
- Formats : PDF
View record
-
Improvement of the AMR's performance: multi-seg...
- Author(s) : LIONTE S., RISSER M., VASILE C., et al.
- Date : 2016/09/11
- Languages : English
- Source: 7th International Conference on Magnetic Refrigeration at Room Temperature (Thermag VII). Proceedings: Turin, Italy, September 11-14, 2016.
- Formats : PDF
View record
-
Evaluation of the performance of a thermal swit...
- Author(s) : PETELIN N., VOZEL K., KLINAR K., TOMC U., KITANOVSKI A.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
A lower temperature difference of the elastocal...
- Author(s) : LIU B., WANG Y., ZHU Z., THEODORAKIS P. E., SONG J., BENNACER R.
- Date : 2023/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 155
- Formats : PDF
View record
-
Performance characteristics of a regeneration E...
- Author(s) : DIGUET G., LIN G., CHEN J.
- Date : 2013/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 3
- Formats : PDF
View record