Pool boiling heat transfer. 2. Thickness of liquid macrolayer formed beneath vapour masses.

Author(s) : KUMADA T., SAKASHITA H.

Type of article: Article

Summary

The critical heat flux and the detachment frequency were measured on 20 mm diameter horizontal and vertical heated disks at pressures of 0.03-0.4 megapascal with water, ethanol, methanol and acetone. Two semi-empirical correlations are proposed.

Details

  • Original title: Pool boiling heat transfer. 2. Thickness of liquid macrolayer formed beneath vapour masses.
  • Record ID : 1995-3460
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 38 - n. 6
  • Publication date: 1995/04