REDUCTION OF RADIATION ERRORS IN THERMAL CONDUCTIVITY MEASUREMENTS ABOVE 100 K.
Author(s) : TALPE J. H.
Type of article: Article
Summary
A STEADY-STATE METHOD FOR THERMAL CONDUCTIVITY MEASUREMENTS ABOVE 100 K ON POOR CONDUCTORS IS DESCRIBED. RADIATION ERRORS ARE MADE NEGLIGIBLE USING A CLOSELY FITTING SHIELD WITH A TEMPERATURE PROFILE MATCHED ALONG ITS LENGTH TO THAT OFTHE SAMPLE. CALCULATIONS SHOW THAT FOR A TYPICAL GEOMETRY, THE RADIATION ERROR AT ROOM TEMPERATURE IS TWO OR THREE ORDERS OF MAGNITUDE LOWER THAN FOR A SHIELD KEPT AT TESNEPRT THE EXPERIMENTAL SETUP IS DESCRIBED AND MEASUREMENTS ON POLYMETHYLMETHACRYLATE ARE REPORTED.
Details
- Original title: REDUCTION OF RADIATION ERRORS IN THERMAL CONDUCTIVITY MEASUREMENTS ABOVE 100 K.
- Record ID : 1992-0148
- Languages: English
- Source: Rev. sci. Instrum. - vol. 62 - n. 4
- Publication date: 1991/04
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (2)
See the source
Indexing
- Themes: Thermodynamic measurements
- Keywords: Thermal conductivity; Measurement
-
THE END-EFFECT ERROR IN THE DETERMINATION OF TH...
- Author(s) : KNIBBE P. G.
- Date : 1986
- Languages : English
- Source: International Journal of Heat and Mass Transfer - vol. 29 - n. 3
View record
-
A MATHEMATICAL MODEL OF A RAMP FORCED HOTWIRE T...
- Author(s) : MOHAMMADI S. S., GRABOSKI M. S., SLOAN E. D.
- Date : 1981/04
- Languages : English
- Source: International Journal of Heat and Mass Transfer - vol. 24 - n. 4
View record
-
MEASUREMENT OF THERMAL CONDUCTIVITIES OF GLASSY...
- Author(s) : COTTS E. J., ANDERSON A. C.
- Date : 1984
- Languages : English
- Source: Rev. sci. Instrum. - vol. 55 - n. 2
View record
-
MEASUREMENT OF LOW THERMAL CONDUCTIVITY COEFFIC...
- Author(s) : SCHNEIDER M.
- Date : 1982
- Languages : German
View record
-
THERMAL CONDUCTIVITY MEASUREMENT FROM 30 TO 750 K.
- Author(s) : CAHILL D. G.
- Date : 1990
- Languages : English
- Source: Rev. sci. Instrum. - vol. 61 - n. 2
View record