REFRIGERANT CHARGE EFFECTS ON HEAT PUMP PERFORMANCE.

Author(s) : DAMASCENO G. S.

Summary

THE CAPABILITY OF PREDICTING THE EFFECTS OF REFRIGERANT CHARGE ON THE STEADY-STATE PERFORMANCE OF A HEAT PUMP IS ADDRESSED. RATHER EXTENSIVE TEST DATA FOR ONE PARTICULAR RESIDENTIAL AIR-TO-AIR HEAT PUMP ARE COMPARED WITH THE PREDICTIONS OF HPSIM, A COMPUTER MODEL WITH THE CAPABILITY OF TRACKING REFRIGERANT MASS DISTRIBUTION WITHIN THE VARIOUS COMPONENTS.

Details

  • Original title: REFRIGERANT CHARGE EFFECTS ON HEAT PUMP PERFORMANCE.
  • Record ID : 1992-1877
  • Languages: English
  • Publication date: 1991
  • Source: Source: ASHRAE Trans.
    vol. 97; n. 1; 304-310; 10 fig.; 1 tabl.; 11 ref.; discuss.