Research of pulse tube refrigerator with high and low temperature double-inlet.

Author(s) : YANG L., ZHOU Y., LIANG J.

Type of article: Article

Summary

Through analyzing phase relation between pressures and flow characteristics of double-inlet and multi-bypass, mechanism of double-inlet to lower the temperature of pulse tube refrigerator is proposed. Then another proposal is put forward to replace the low temperature multi-bypass valve, which is another double-inlet valve at room temperature and a small tube prolonging to the low temperature part of pulse tube. Through experiment, this multi-double-inlet version proves effective to lower the refrigeration temperature. Test acquires a lowest temperature of 37 K with two double inlet valves and 50 K with one double inlet valve. The concept of low temperature double-inlet is proposed here for the first time.

Details

  • Original title: Research of pulse tube refrigerator with high and low temperature double-inlet.
  • Record ID : 2000-2337
  • Languages: English
  • Source: Cryogenics - vol. 39 - n. 5
  • Publication date: 1999/05

Links


See other articles in this issue (2)