Research on the characteristics of variable frequency chilled water pumps in central air-conditioning systems. 2. Simulation and analysis.
[In Chinese. / En chinois.]
Author(s) : WANG H. D.
Type of article: Article
Summary
Simulation was carried out for an air conditioning system with a new model, based on the chilled water-loop resistance characteristics and previous work comparison between the new model and the pump's affinity laws. Results show that applying the latter to determine parameters of VFD (variable frequency drive) chilled water pumps will result in obvious deviation and underestimate the head and energy consumption of the pumps, since the effects of constant pressure difference and variable resistance coefficients of chilled water loop are not taken into account. Meanwhile, the relationships among the Reynolds number Re, friction resistance coefficient lambda, resistance coefficient of chilled water loop S and air conditioning loads are inspected respectively. The influences of load distribution, constant pressure difference, etc. on energy consumption are also analysed in detail. The most advantageous and most disadvantageous operating conditions are also obtained from the analysis and results. Some suggestions for VFD chilled water pump system design are brought forward at the end of this article.
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 2004-1740
- Languages: Chinese
- Source: Refrigeration - vol. 84 - n. 3
- Publication date: 2003/09
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (2)
See the source
Indexing
-
VFD-enclosure variable cooling load. 2.
- Author(s) : BURD A. L., BURD G. S.
- Date : 2015/03
- Languages : English
- Source: HPAC Engineering - vol. 87 - n. 3
View record
-
IKK 2006 et les économies d'électricité : la va...
- Date : 2006/12
- Languages : French
- Source: Chaud Froid Plomb. - n. 696
View record
-
Energy efficiency analysis for chilled water pl...
- Author(s) : YANG Q., ZONG W., YANG D., et al.
- Date : 2014/06
- Languages : Chinese
- Source: HV & AC - vol. 44 - n. 291
- Formats : PDF
View record
-
Les pompes à vitesse variable et l'équilibrage.
- Author(s) : PETITJEAN R.
- Date : 1993/10
- Languages : French
- Source: Chaud Froid Plomb. - vol. 47 - n. 551
View record
-
Further study on the inherent operating charact...
- Author(s) : LI Z., XU X., DENG S., et al.
- Date : 2014/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 66 - n. 1-2
View record