Summary
A SIMPLE HEAT EXCHANGER USING SILVER POWDER FOR COOLING PURE LIQUID HELIUM 3 IS DESCRIBED. THE TEMPERATURE DIFFERENCE ACROSS THE HEAT EXCHANGER WAS LESS THAN 5 MICROK AT THE SUPERFLUID TRANSITION OF HELIUM 3 WITH A THERMAL FLUX OF 0.06 NANOW.
Details
- Original title: SMALL HEAT EXCHANGER USING SILVER POWDER.
- Record ID : 1988-0458
- Languages: English
- Source: Cryogenics - vol. 27 - n. 8
- Publication date: 1987