SURFACE TEMPERATURE MEASUREMENT ERRORS.

Author(s) : KELTNER N. R., BECK J. V.

Type of article: Article

Summary

MATHEMATICAL MODELS, DEVELOPED FOR THE RESPONSE OF SURFACE MOUNTED THERMOCOUPLES ON A THICK WALL, ACCOUNT FOR THE SIGNIFICANT CAUSES OF ERRORS IN BOTH THE TRANSIENT AND STEADY STATE RESPONSE TO CHANGES IN THE WALL TEMPERATURE. IN MANY CASES, CLOSED FORM ANALYTICAL EXPRESSIONS ARE GIVEN FOR THE RESPONSE. THE CASES FOR WHICH ANALYTICAL EXPRESSIONS ARE NOT OBTAINABLE CAN BE EASILY EVALUATED ON A PROGRAMMABLE CALCULATOR.

Details

  • Original title: SURFACE TEMPERATURE MEASUREMENT ERRORS.
  • Record ID : 1984-0044
  • Languages: English
  • Source: J. Heat Transf. - vol. 105 - n. 2
  • Publication date: 1983/05
  • Document available for consultation in the library of the IIR headquarters only.