TECHNIQUE ABOUT SELF-CYCLING ABSORBING OF PARTIAL LIQUID OXYGEN IN A CONDENSER-EVAPORATOR USING A PLATE-FIN HEAT SIPHON EVAPORATOR INSTEAD OF A LIQUID OXYGEN PUMP FOR LARGE AIR SEPARATION PLANTS.

[In Chinese. / En chinois.]

Author(s) : CHEN X. S.

Type of article: Article

Summary

IT WAS FOUND THAT THE RATE OF LIQUID OXYGEN SELF-CYCLING IN 1,000 AND 6,000 NM3/H PLANT CAN ATTAIN DESIGN REQUIREMENTS AND THE CONDENSER-EVAPORATOR CAN BE RENDERED ANTI-EXPLOSIVE. IT IS ALSO PUT FORWARD THAT THE METHOD SHOULD BE USED TO REVISE THE LOCKHART-MARTINELLI FORMULA FOR CALCULATING RESISTANCE IN TWO-PHASE FLOW IN PLATE-FIN PASSAGES.

Details

  • Original title: [In Chinese. / En chinois.]
  • Record ID : 1984-2184
  • Languages: Chinese
  • Source: J. chin. Assoc. Refrig. - n. 4
  • Publication date: 1983/12
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (50)
See the source