A performance evaluation of the HVAC-based nozzles.
Author(s) : KHAN I. M.
Summary
An investigation of the modelling of the JETs (Jet Environmental Techniques, UK) existing nozzle and its performance is compared with De Laval's nozzle in the near flow field; when the turbulent jet from the nozzle interacted with the surrounding still ambient fluid under identical inlet and contraction section of the nozzle geometry. The flow is modelled by means of RNG kappa-epsilon turbulence model under steady state conditions. Prototype experiments were carried out with JETs existing nozzle geometry in a test room was validated numerically. Examination of the turbulence kinetic energy, the entrainment ratio and the temperature profiles in the numerical space revealed that diffusion was enhanced between the jet flows and the still ambient fluid is noticed for the JETs nozzle geometry.
Details
- Original title: A performance evaluation of the HVAC-based nozzles.
- Record ID : 2007-0757
- Languages: English
- Source: ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
- Publication date: 2006/05/21
Links
See other articles from the proceedings (161)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Geometry; Measurement; Manufacturer; Nozzle; Air diffuser; Flow rate; Air conditioning
-
Detailed measurements of airflow characteristic...
- Author(s) : CHUAH Y. K., HU S. C., BARBER J. M.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record
-
Regulacija varijabilnog vrtloznog difuzora bez ...
- Author(s) : ZGAVEC D.
- Date : 2005/11/02
- Languages : Serbian
- Source: Zbornik radova pisanih za 36. kongres o klimatizaciji, grejanju, hladenju + CD-ROM./ Proceedings of the 36th International HVAC&R congress + CD-ROM.
View record
-
The effect of various air-terminal geometries o...
- Author(s) : STEIMLE F., SCHADLICH S.
- Date : 1994/11/16
- Languages : German
- Source: DKV-Tagungsbericht 1994 Bonn.
View record
-
The influence of heat and contaminant source no...
- Author(s) : HAGSTRÖM K. H., ZHIVOV A. M., SIRÉN K., et al.
- Date : 1999
- Languages : English
- Source: ASHRAE Transactions. 1999 Annual Meeting, Seattle, Washington + CD-ROM.
View record
-
Experimental study of indoor thermal environmen...
- Author(s) : KASHIRAJIMA Y., SUGIURA T., TAKAHASHI M., et al.
- Date : 2002
- Languages : English
- Source: ASHRAE Transactions. 2002 annual Meeting, Honolulu, Hawaii. Volume 108, part 2 + CD-ROM.
View record