Recommended by the IIR / IIR document
Applying a variable geometry ejector in a solar ejector refrigeration system.
Author(s) : VAN NGUYEN V., VARGA S., SOARES J., DVORAK V., OLIVEIRA A. C.
Type of article: IJR article
Summary
This paper presents an experimental study of the influence of a variable geometry ejector (VGE) design on the performance of a small-scale, 1.5 kW nominal capacity solar heat driven ejector air-conditioning system under real-life working conditions. Under variable operating conditions (e.g. solar radiation, ambient temperature) fixed geometry ejector performs poorly, therefore the objective of the present work was to prove the benefit of the VGE concept. In the experimentally tested VGE the area ratio through a movable spindle (SP) and the nozzle exit position (NXP) can be adjusted in order to respond to the operating conditions. The results showed very stable operation of the cooling cycle during the experiments. Both NXP, SP had considerable influences on the cooling cycle performance. An optimal NXP was identified, which did not change with various operating conditions. Similarly, SP also showed an optimum; however, the optimum point depended strongly on the operating conditions. The results clearly indicated the benefit of using the VGE design over the fixed geometry. COP improvement was as high as 24% with a maximum of 0.29 corresponding to a cooling capacity of 1.6 kW when compared to a fixed geometry ejector. The study also confirmed the importance of using a variable-speed pump in the ejector cycle
Available documents
Format PDF
Pages: 187-195
Available
Free
Details
- Original title: Applying a variable geometry ejector in a solar ejector refrigeration system.
- Record ID : 30027426
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 113
- Publication date: 2020/05
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2020.01.018
Links
See other articles in this issue (28)
See the source
Indexing
-
Experimental results with a variable geometry e...
- Author(s) : PEREIRA P. R., VARGA S., SOARES J., et al.
- Date : 2014/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 46
- Formats : PDF
View record
-
Numerical and experimental investigation of sol...
- Author(s) : BUTRYMOWICZ D., SMIERCIEW K., GAGAN J., et al.
- Date : 2012/09/18
- Languages : English
- Source: EuroSun 2012: solar energy for a brighter future. ISES-Europe solar conference. Conference proceedings: Rijeka, Croatia, 18-20 September 2012.
- Formats : PDF
View record
-
CFD study of a variable area ratio ejector usin...
- Author(s) : VARGA S., LEBRE P. M. S., OLIVEIRA A. C.
- Date : 2013/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
View record
-
Thermoeconomic optimization of an ejector refri...
- Author(s) : CHEN J., HAVTUN H., PALM B.
- Date : 2014/08/02
- Languages : English
- Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
View record
-
Analysis of application of two-phase injector i...
- Author(s) : SMIERCIEW K., BUTRYMOWICZ D., KWIDZINSKI R., et al.
- Date : 2015/03
- Languages : English
- Source: Applied Thermal Engineering - vol. 78
View record